MS-820 will not match slave data. Here's a table of daisy chain
functions I made a few years ago:
Scanner Software # Match code Ordered output Output
formatting S&E Trigger
Quadrus EZ 35-676001-17 Yes No Yes No*
MS-880 35-558001-17 Yes Yes** Yes No*
MS-850 35-338501-17 No N/A N/A N/A
MS-820 35-338201-17 No N/A N/A N/A
MS-911 35-559001-22 Yes N/A N/A N/A
MS-3 Laser 35-343001-13 No N/A N/A Yes***
MS-860 35-338601-14 Yes
* When S&E are set to any value other than NULL, the S&E
triggers are sent to the slave instead of the serial trigger character.
** Code type function is not applied to slave data
***using S&E, the serial trigger character is sent to the slave.
Juan Worle
Technical Service Representative
Ph: (425) 226-5700 x1156
Fx: (425) 254-9295